Evidence & Data

Most battery sites publish a specification table. We publish the datasets behind ours — including the claims we cannot yet verify. Everything below is the same JSON that drives the product pages, in machine-readable form, so a buyer (or an AI assistant) can check any figure instead of taking it on trust.

Direct Answer

14 model records (4 first-party confirmed, 6 third-party reference, 4 on request only), 25 tracked claims and 10 registered sources — 4 independent standards (level 1), 1 manufacturer documentation (level 2) and 5 third-party catalogs (level 3). Fields the manufacturer does not publish are left null, never estimated.

Datasets

Claim ledger

Every figure asserted across the site maps to one of these claims, each carrying its entity, value, unit, evidence level and verification status. "Verified (first-party)" means the value comes from our own engineering datasheet; "reference" means it is compiled from third-party catalogs and is not a DINWEYS published stock rating; "needs verification" means we have not yet obtained a document that would support it.

Evidence levels

  • Level 1 — DINWEYS / Chengguang first-party documentation — verification_status 'VERIFIED (first-party)'
  • Level 2 — Official standards / government / institutional sources — verification_status 'VERIFIED'
  • Level 3 — Credible industry sources — verification_status 'VERIFIED' or 'REFERENCE'
  • Level 4 — Independent fitment / reference sources — verification_status 'REFERENCE (third-party catalogs)'
  • Level 5 — Unverified / community information — verification_status 'NEEDS_VERIFICATION'
IDClaimEntityValueStatusEvidenceSource
C-001 DINWEYS is the brand; Chengguang Power Tech Co., Ltd. is the manufacturer DINWEYS (brand) / Chengguang Power Tech Co., Ltd. (manufacturer) — Verified (HIGH) Level 1 DINWEYS manufacturer specification
C-006 IATF 16949 / ISO 9001:2015 / ISO 45001:2018 certification Chengguang Power Tech Co., Ltd. — FIRST-PARTY (manufacturer-reported) (FIRST-PARTY) Level 5 DINWEYS manufacturer specification
C-007 200,000 m² facility, 18 automated lines, 40,000 batteries/day Chengguang Power Tech Co., Ltd. — FIRST-PARTY (manufacturer-reported) (FIRST-PARTY) Level 5 DINWEYS manufacturer specification
C-008 N70/N100/N120/N220/DIN66/DIN74 are third-party reference (NOT DINWEYS published stock) N70 / N100 / N120 / N220 / DIN66 / DIN74 — Reference (third-party catalogs) (MEDIUM) Level 4 Third-party fitment reference — not OEM confirmation
C-009 CCA values across SAE/EN/JIS/DIN/IEC are not directly comparable CCA (cross-standard comparability) — Verified (HIGH) Level 2 Official standard
BAT-145G51-VOLTAGE Nominal voltage 145G51 (N150) 12 V Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-145G51-CAPACITY Rated capacity (C20, 20-hour rate) 145G51 (N150) 135 Ah Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-145G51-CCA Cold cranking amps 145G51 (N150) 900 A Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-145G51-RC Reserve capacity 145G51 (N150) 220 min Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-145G51-DIMENSIONS Case dimensions (L×W×H) 145G51 (N150) 508×222×212 mm Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-190H52-VOLTAGE Nominal voltage 190H52 (N200) 12 V Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-190H52-CAPACITY Rated capacity (C20, 20-hour rate) 190H52 (N200) 200 Ah Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-190H52-CCA Cold cranking amps 190H52 (N200) 1100 A Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-190H52-RC Reserve capacity 190H52 (N200) 320 min Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-190H52-DIMENSIONS Case dimensions (L×W×H) 190H52 (N200) 520×278×220 mm Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-58827-VOLTAGE Nominal voltage 58827 (DIN88) 12 V Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-58827-CAPACITY Rated capacity (C20, 20-hour rate) 58827 (DIN88) 88 Ah Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-58827-CCA Cold cranking amps (EN) 58827 (DIN88) 800 A Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-58827-RC Reserve capacity 58827 (DIN88) 150 min Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-58827-DIMENSIONS Case dimensions (L×W×H) 58827 (DIN88) 353×175×190 mm Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-60038-VOLTAGE Nominal voltage 60038 (DIN100) 12 V Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-60038-CAPACITY Rated capacity (C20, 20-hour rate) 60038 (DIN100) 100 Ah Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-60038-CCA Cold cranking amps (EN) 60038 (DIN100) 870 A Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-60038-RC Reserve capacity 60038 (DIN100) 170 min Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification
BAT-60038-DIMENSIONS Case dimensions (L×W×H) 60038 (DIN100) 393×175×190 mm Verified (first-party) (HIGH) Level 1 DINWEYS manufacturer specification

Source registry

IDLevelTypeSource
S-JIS-D5301 Level 1 standard
S-EN-50342-1 Level 1 standard
S-SAE-J537 Level 1 standard
S-BCI-GROUP Level 1 standard
S-CG-DATASHEET Level 2 manufacturer doc
S-BRAVA-N70 Level 3 third party catalog
S-SEBANG-JIS Level 3 third party catalog
S-UPLUS-N220 Level 3 third party catalog
S-LANDPORT-DIN74 Level 3 third party catalog
S-KINGPOWER-DIN66 Level 3 third party catalog

Model verification status

4 models carry a first-party DINWEYS specification; 6 are listed as third-party reference only (widely used group sizes we do not publish as stock ratings); 4 are made to order with no published specification. The per-model breakdown is in battery-master-data.json.

ModelGroupVoltageCapacityCCAStatusSource
145G51 N150 12V 135 Ah 900 A (JIS D5301) confirmed first party DINWEYS manufacturer specification (first-party) + cross-reference Club Assist / Century Batteries fitment guides
190H52 N200 12V 200 Ah 1100 A (JIS D5301) confirmed first party DINWEYS manufacturer specification (first-party) + cross-reference Club Assist / Century Batteries fitment guides
58827 DIN88 12V 88 Ah 800 A (EN 50342-1) confirmed first party DINWEYS manufacturer specification (first-party)
60038 DIN100 12V 100 Ah 870 A (EN 50342-1) confirmed first party DINWEYS manufacturer specification (first-party)
Group 31 31 12V — not published on request DINWEYS made-to-order BCI line (no published stock specification)
Group 8D 8D 12V — not published on request DINWEYS made-to-order BCI line (no published stock specification)
Group 4D 4D 12V — not published on request DINWEYS made-to-order BCI line (no published stock specification)
65D31R N70 12V 70 Ah 580 A (JIS D5301) reference Third-party reference: BRAVA N70 (65D31R) datasheet, Western Battery N70, BCI Group Sizes (Group 27 = 65D31R)
95E41R N100 12V 100 Ah 730 A (JIS D5301) reference Third-party reference: Sebang JIS catalog (SMF N100 = 95E41R), BCI Group Sizes
N120 N120 12V 120 Ah 820 A (JIS D5301) reference Third-party reference: Sebang JIS catalog (SMF N120), Continental Group N120
245H52 N220 12V 220 Ah 1200 A (JIS D5301) reference Third-party reference: UPLUS JIS catalog (245H52R = N220), Powsea 245H52
56638 DIN66 12V 66 Ah not published reference Third-party reference: King Power DIN66 (56638), Xiamen Songli DIN66 (56638mf)
57412 DIN74 12V 74 Ah 680 A (EN 50342-1) reference Third-party reference: Landport 57412 datasheet, Marvel Battery 57412
Group 6D 6D 12V — not published on request DINWEYS made-to-order BCI line + BCI Group Sizes reference dimensions

Fitment confidence levels

Industry reference, not DINWEYS official OEM confirmation. Always confirm group size, terminal type, terminal orientation, polarity and tray dimensions against the specific vehicle before ordering. A listed compatible reference is not an OEM replacement.

  • HIGH — Multiple credible sources or manufacturer documentation
  • MEDIUM — Credible independent source with matching technical parameters
  • LOW — Limited third-party reference
  • UNVERIFIED — Insufficient evidence

Verification policy

Fields not published by the manufacturer are left null and marked 'unverified'. Third-party catalog/industry reference specifications are marked 'reference' and always carry source + source_url. Ratings are never interpolated or assumed. Specifications vary by manufacturer — always confirm against the specific vehicle.

  • tier1 — Manufacturer datasheet, standards organizations (JIS D5301, EN 50342-1, SAE J537)
  • tier2 — Independent commercial-vehicle fitment guides (Club Assist, Century Batteries)
  • tier3 — Third-party battery catalogs (Bosch, Yuasa, SSB, Powsea)

Frequently Asked Questions

Why are some fields in the datasets empty?

Because the manufacturer does not publish them. The policy is stated in the master data itself: fields that are not published are left null and never estimated or interpolated. An empty field means "not published", not "zero".

What does "reference" mean in the model data?

It means the value was compiled from third-party catalogs rather than a DINWEYS datasheet. Those models are listed so you can cross-reference a replacement; they are not DINWEYS published stock ratings and are quoted on request if you need them.

How current are these datasets?

Each JSON file carries its own dateModified value, shown next to the dataset name above. The claim ledger and source registry are updated whenever a claim's status changes — including when a claim is still marked as needing verification.

Request a Datasheet & Certificate Browse Model Specifications

Technical review — Reviewed by the DINWEYS technical team. Manufacturer: Chengguang Power Tech Co., Ltd. Data source: manufacturer specification and test documentation. Specifications vary by model and standard; confirm final values with the manufacturer.